Disinfection of Platinum primary tooth file is an important part of ensuring the safety of medical operations and preventing cross infection. Common disinfection methods are mainly as follows.

High temperature and high pressure steam sterilization is a common and effective method. Place the Platinum primary tooth file in a special sterilization container and then place it in a high temperature and high pressure steam sterilization device. Under certain temperature, pressure and time conditions, it can kill various microorganisms including spores. However, it should be noted that high temperature and high pressure may cause a certain degree of loss to some parts of the deciduous tooth file, so it is necessary to balance the number of sterilizations and the life of the instrument.

Chemical disinfection is also an option. Disinfectants such as glutaraldehyde can be used, but when using chemical disinfectants, the instructions for use of the disinfectant must be strictly followed, including soaking time, concentration, etc. After disinfection, it is also necessary to rinse thoroughly with sterile water to remove residual disinfectants and prevent irritation to oral tissues.

Ethylene oxide sterilization is another feasible method. It can penetrate the packaging material, fully sterilize the instrument, and cause less damage to the instrument. However, this method requires special equipment and the sterilization cycle is relatively long.

In addition, dry heat sterilization can also be used to sterilize Platinum primary tooth files. Sterilization is carried out in a high-temperature and dry environment, but this method takes a long time to sterilize and requires high thermal stability of the instrument.

In actual operation, multiple factors need to be considered when choosing a disinfection method. For example, the equipment conditions of the medical institution, the efficiency of disinfection, the degree of damage to the instrument, and the cost.

At the same time, no matter which disinfection method is used, it is necessary to ensure the standardization and effectiveness of the disinfection process. Regularly inspect and maintain the disinfection equipment to ensure its normal operation; monitor the disinfection effect, such as using biological indicators, to ensure that the Platinum primary tooth file meets the sterility requirements.

In addition, before and after disinfection, the Platinum primary tooth file needs to be properly packaged and stored to prevent contamination during transportation and storage.

For example, a small dental clinic that does not have ethylene oxide sterilization equipment and needs to quickly disinfect the Platinum primary tooth file may choose high-temperature and high-pressure steam sterilization. However, for large dental hospitals, due to the large number of instruments, multiple disinfection methods may be flexibly used according to different instrument characteristics and needs.

In short, the correct selection and implementation of the disinfection method of Platinum primary tooth file is of great significance to ensure the safety of patients and the quality of medical care.
×